NVIDIA OSFP Part-Number Crosswalk: Mellanox MMA/MMS to NVIDIA 980- Numbers
NVIDIA is transitioning its transceiver and cable catalog from Mellanox part numbers to NVIDIA part numbers. Old BOMs and purchase histories carry the Mellanox number. New quotes increasingly carry the NVIDIA one. They are the same physical parts, and for a while yet you will see both in the same procurement thread.
This page is the crosswalk. It maps the 400G and 800G NDR-generation range to form factor, optics, reach and — the part most catalogs leave out — which end of the link each part belongs in.
Working from a quote or a PO right now? Send us the part number and the switch and NIC models. We will tell you whether it is the right part, including when the answer is one we do not sell. Ask us →
The crosswalk
| Mellanox P/N | NVIDIA P/N | Form factor | Speed | Optics | Connector | Reach | Belongs in |
|---|---|---|---|---|---|---|---|
| MMA4Z00-NS400 | 980-9I51S-00NS00 | Single-port OSFP, Flat-Top (RHS) | 400G (4 × 106.125G PAM4) | SR4, 850nm multimode | MPO/MTP-12 APC | 30m OM3 / 50m OM4 | ConnectX-7, ConnectX-8 and DGX single-port OSFP NIC ports. Not BlueField-3 — see below. |
| MMA1Z00-NS400 | not yet confirmed | QSFP112 — not OSFP | 400G (4 × 100G PAM4) | SR4, 850nm multimode | MPO/MTP-12 APC | 30m OM3 / 50m OM4 | BlueField-3 DPUs and ConnectX-7 in QSFP112. Will not physically fit an OSFP cage. |
| MMA4Z00-NS | not yet confirmed | Twin-port OSFP, Finned-Top (IHS) | 800G (8 × 106.125G PAM4) | SR8 (2 × SR4), 850nm multimode | Dual MPO/MTP-12 APC | 30m OM3 / 50m OM4 | Quantum-2 and Spectrum-4 air-cooled switch ports (QM9700, QM9790) |
| MMA4Z00-NS-FLT | not yet confirmed | Twin-port OSFP, Flat-Top | 800G | SR8, 850nm multimode | Dual MPO/MTP-12 APC | 30m OM3 / 50m OM4 | DGX H100 front cages — NVIDIA's documentation specifies flat-top there. Same logic for liquid-cooled ports, where a cold plate needs a flat surface. |
| MMS4X00-NS400 | not yet confirmed | Single-port OSFP | 400G | DR4, 1310nm single-mode | MPO/MTP-12 APC | 500m | Single-mode plants. Different fiber entirely. |
| MMS4X00-NM / MMS4X00-NS | not yet confirmed | Twin-port OSFP | 800G | DR8, single-mode | Dual MPO/MTP-12 APC | 500m class | Single-mode plants. |
On the blanks: we publish an NVIDIA part number only where we have confirmed it with a supplier. 980-9I51S-00NS00 is confirmed for MMA4Z00-NS400. The rest are marked unconfirmed rather than guessed, because a wrong part number on a PO is the exact problem this page exists to prevent. We add them as they are confirmed — ask us if you need one of them today and we will go get it.
BlueField-3 is QSFP112 only
This one deserves its own heading, because it is the most expensive mistake on the page and almost every catalog gets it wrong.
NVIDIA's own module documentation states plainly that BlueField-3 adapters accept QSFP112 devices only, and that OSFP is not for use in BlueField-3 DPUs. A BlueField-3 has no OSFP option at any speed. So the 400G SR4 part for a BlueField-3 is the MMA1Z00-NS400, never the MMA4Z00-NS400.
The two parts carry the same optics — 4 × 100G-PAM4, 850nm VCSEL, one MPO-12/APC connector, 30m OM3 / 50m OM4 — and the same fiber works with either. The only difference is the cage, and the cage is the thing that decides whether the module goes in.
The same trap runs in the other direction at the switch: single-port OSFP modules are not for use in switches, which take the twin-port part.
How to read these part numbers
Three characters do almost all the work.
| Segment | What it tells you |
|---|---|
| MMA vs MMS | MMA is multimode (850nm, SR, OM3/OM4, short reach). MMS is single-mode (1310nm, DR, 500m+). This is the single most consequential character in the string, and it decides which fiber plant the part belongs to. |
| 4Z00 vs 1Z00 vs 4X00 | The family, which carries the cage. 4Z00 and 4X00 are OSFP. 1Z00 is QSFP112 — a physically different cage that will not seat in an OSFP port no matter what the rest of the number says, and the only cage a BlueField-3 has. |
| -NS400 vs -NS | Port count and speed. -NS400 is single-port 400G. -NS is twin-port 800G presenting as 2 × 400G. |
| -FLT suffix | Flat-top build of a part that is otherwise finned. NVIDIA documents it for the DGX H100; the same logic covers liquid-cooled deployments. |
The heatsink tells you which end of the link
This is the part that costs people money, and it is not a spec — it is a fit constraint. Note that it applies to the OSFP family only: QSFP112 has one shape, so if someone is asking which top style you need on a 1Z00 part, they are quoting from the wrong family.
| Old / colloquial name | Current NVIDIA term | What it means |
|---|---|---|
| Flat-top, flat | RHS — Riding Heat Sink | The equipment's heatsink rides on top of the module. The module is flat because the port cage has the cooling. |
| Finned-top, finned | IHS — Integrated Heat Sink | The fins are integrated into the module's own metal top, because the port has no cooling of its own. |
The fins are either on the module or on the equipment. Never both, never neither.
- A finned module in a ConnectX-7 will not seat — the cage heatsink is in the way.
- A flat module in an air-cooled switch seats fine and looks like it worked. There is just no cooling path.
- A finned module in a DGX H100 front cage or a liquid-cooled switch defeats the flat contact surface those need.
The canonical topology: one twin-port finned module in the switch → two MPO-12/APC patch cords → two adapter-side modules in two servers. One switch module serves two servers — for every two server ports, one switch module. Those two adapter-side modules can be OSFP, QSFP112, or one of each; the fiber does not care.
The wrong-order list
| Part ordered | Why it gets ordered | What actually happens |
|---|---|---|
| MMA4Z00-NS400 for a BlueField-3 | Almost every catalog lists BlueField-3 as a host platform for it | It cannot seat. BlueField-3 is QSFP112 only. The correct part is MMA1Z00-NS400. |
| MMA4Z00-NS (finned) for a NIC | "800G is better than 400G" | Won't seat under the cage heatsink. And the ConnectX-7 OSFP port is a 400G port — the extra 400G was never available at that end. |
| MMA4Z00-NS400 (flat) for an air-cooled switch | Assumed flat is universal | Seats, links, no cooling path. The failure is thermal and it shows up later. |
| MMA4Z00-NS (finned) for a DGX H100 front cage | Didn't know the -FLT variant exists | Fins defeat the flat contact surface. MMA4Z00-NS-FLT is the correct part. |
| MMA1Z00-NS400 for an OSFP port | Same "NS400" suffix, similar description | QSFP112 cage. Will not physically fit an OSFP port. |
| MMS4X00-NS400 | One character different from MMA4X00 | Single-mode DR4 at 1310nm. Wrong fiber plant. |
What we stock
New, lifetime warranty backed by Resilient Tec, shipping from Knoxville, Tennessee.
- 400G OSFP SR4 Flat-Top (RHS) — MMA4Z00-NS400 / 980-9I51S-00NS00 compatible — $579.00, the OSFP server-side module
- 400G QSFP112 SR4 — MMA1Z00-NS400 compatible — $549.00, the BlueField-3 and ConnectX-7 QSFP112 module
- 800G OSFP SR8 Finned-Top (IHS) twin-port — MMA4Z00-NS compatible — $829.00, the switch-side module
- 400G OSFP DR4 Flat-Top — MMS4X00-NS400 compatible — single-mode, sourced to order
- MPO-12/APC OM4 Type B trunk cable — $59.00 to $139.00, the fiber all of the multimode parts above need
- MPO-12/APC 1:2 splitter cables — built to order, for NDR200 fan-out
We do not stock the flat-top 800G (MMA4Z00-NS-FLT) or the MMS 800G single-mode range. If that is what your build needs, that is what we will tell you.
Populating a cluster? Tell us the port count and we will quote the switch-side and server-side modules together. In-stock quantities are small by design; additional units ship on a 7–10 day lead time.
Related reading
- Flat-Top or Finned-Top OSFP? How to Tell Which Module Your ConnectX-7 Actually Needs
- Does the MMA4Z00-NS400 Work With My System? ConnectX-7, BlueField-3, Quantum-2 and DGX H100
- MPO-12/APC vs UPC: Why Your Existing Fiber Won't Work With NDR Optics
- OSFP vs. QSFP-DD: A Practical Breakdown for GPU Clusters
- OSFP DAC Cables: What They Are and When to Use One
- NVIDIA & Mellanox Interconnect Compatibility Guide
- DGX Spark Interconnect Reference
You might also need
- MPO and fiber optic patch cords — the fiber between the two modules
- DAC cables and AOC cables — when copper or active optical beats a transceiver pair
- Network switches — Arista, Cisco, HPE/Aruba and Mellanox, new and tested pre-owned