{"product_id":"pdumnv30hv2lx-tripp-lite-pdu-monitored-208-240v-30a-36-c13-6-c19-outlets-l6-30p-lx-interface-10-ft-cord-0urm-taa-new","title":"PDUMNV30HV2LX, Tripp Lite PDU Monitored 208\/240V 30A 36 C13 6 C19 Outlets L6-30P LX Interface 10 ft Cord 0URM TAA, New","description":"\u003cp\u003eCondition: New\u003c\/p\u003e\n\u003cp data-start=\"382\" data-end=\"587\"\u003eThe \u003cstrong data-start=\"386\" data-end=\"409\"\u003eEaton PDUMNV30HV2LX\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"432\" data-end=\"454\"\u003emonitored rack PDU\u003c\/strong\u003e designed for modern data centers, AI infrastructure, and network environments requiring reliable, high-density power distribution.\u003c\/p\u003e\n\u003cp data-start=\"589\" data-end=\"799\"\u003eWith \u003cstrong data-start=\"594\" data-end=\"649\"\u003ereal-time remote monitoring via Eaton’s LX Platform\u003c\/strong\u003e, this 0U vertical PDU allows IT teams to track load levels, optimize capacity, and prevent overload conditions—without taking up valuable rack space.\u003c\/p\u003e\n\u003cp data-start=\"801\" data-end=\"956\"\u003eIdeal for \u003cstrong data-start=\"811\" data-end=\"866\"\u003eserver racks, network closets, and edge deployments\u003c\/strong\u003e, it delivers \u003cstrong data-start=\"880\" data-end=\"911\"\u003e5.5kW of single-phase power\u003c\/strong\u003e with a versatile mix of C13 and C19 outlets.\u003c\/p\u003e\n\u003chr data-start=\"958\" data-end=\"961\"\u003e\n\u003ch2 data-section-id=\"1yslboj\" data-start=\"963\" data-end=\"983\"\u003e Key Features\u003c\/h2\u003e\n\u003cul data-start=\"985\" data-end=\"1895\"\u003e\n\u003cli data-section-id=\"1hb8iu3\" data-start=\"985\" data-end=\"1143\"\u003e\n\u003cstrong data-start=\"987\" data-end=\"1021\"\u003eMonitored PDU with LX Platform\u003c\/strong\u003e\n\u003cul data-start=\"1024\" data-end=\"1143\"\u003e\n\u003cli data-section-id=\"wyezt0\" data-start=\"1024\" data-end=\"1091\"\u003eRemote access via web, SNMP, SSH, or network management systems\u003c\/li\u003e\n\u003cli data-section-id=\"5kanf6\" data-start=\"1094\" data-end=\"1143\"\u003eReal-time load monitoring to prevent downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1exk9m5\" data-start=\"1145\" data-end=\"1334\"\u003e\n\u003cstrong data-start=\"1147\" data-end=\"1170\"\u003eHigh Power Capacity\u003c\/strong\u003e\n\u003cul data-start=\"1173\" data-end=\"1334\"\u003e\n\u003cli data-section-id=\"1wtngy3\" data-start=\"1173\" data-end=\"1214\"\u003e30A input (derated to 24A continuous)\u003c\/li\u003e\n\u003cli data-section-id=\"1fju9sm\" data-start=\"1217\" data-end=\"1258\"\u003eSupports \u003cstrong data-start=\"1228\" data-end=\"1256\"\u003e208V \/ 230V environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ki81v6\" data-start=\"1261\" data-end=\"1334\"\u003eUp to \u003cstrong data-start=\"1269\" data-end=\"1294\"\u003e5.5kW output capacity\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f4lcll\" data-start=\"1336\" data-end=\"1448\"\u003e\n\u003cstrong data-start=\"1338\" data-end=\"1365\"\u003e42 Outlet Configuration\u003c\/strong\u003e\n\u003cul data-start=\"1368\" data-end=\"1448\"\u003e\n\u003cli data-section-id=\"1itzdql\" data-start=\"1368\" data-end=\"1388\"\u003e(36) C13 outlets\u003c\/li\u003e\n\u003cli data-section-id=\"dx0yzt\" data-start=\"1391\" data-end=\"1448\"\u003e(6) C19 outlets \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5nvp6w\" data-start=\"1450\" data-end=\"1584\"\u003e\n\u003cstrong data-start=\"1452\" data-end=\"1488\"\u003e0U Vertical Mount (Space-Saving)\u003c\/strong\u003e\n\u003cul data-start=\"1491\" data-end=\"1584\"\u003e\n\u003cli data-section-id=\"6ydbki\" data-start=\"1491\" data-end=\"1522\"\u003eMounts in rack side channel\u003c\/li\u003e\n\u003cli data-section-id=\"rqm4h0\" data-start=\"1525\" data-end=\"1584\"\u003ePreserves rack U-space for revenue-generating equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aswg95\" data-start=\"1586\" data-end=\"1707\"\u003e\n\u003cstrong data-start=\"1588\" data-end=\"1609\"\u003eNEMA L6-30P Input\u003c\/strong\u003e\n\u003cul data-start=\"1612\" data-end=\"1707\"\u003e\n\u003cli data-section-id=\"ntdysb\" data-start=\"1612\" data-end=\"1707\"\u003eIncludes \u003cstrong data-start=\"1623\" data-end=\"1643\"\u003e10 ft power cord\u003c\/strong\u003e for flexible deployment \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1twoavp\" data-start=\"1709\" data-end=\"1895\"\u003e\n\u003cstrong data-start=\"1711\" data-end=\"1743\"\u003eEnterprise-Grade Reliability\u003c\/strong\u003e\n\u003cul data-start=\"1746\" data-end=\"1895\"\u003e\n\u003cli data-section-id=\"crdyf6\" data-start=\"1746\" data-end=\"1805\"\u003eDesigned for \u003cstrong data-start=\"1761\" data-end=\"1803\"\u003edata centers \u0026amp; critical infrastructure\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uxia8y\" data-start=\"1808\" data-end=\"1895\"\u003eTAA compliant (government \u0026amp; enterprise ready)\n\u003ch2 data-section-id=\"1ltwakc\" data-start=\"1902\" data-end=\"1924\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1926\" data-end=\"2259\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1926\" data-end=\"1947\"\u003e\n\u003ctr data-start=\"1926\" data-end=\"1947\"\u003e\n\u003cth data-start=\"1926\" data-end=\"1936\" data-col-size=\"sm\" class=\"align-top\"\u003eFeature\u003c\/th\u003e\n\u003cth data-start=\"1936\" data-end=\"1947\" data-col-size=\"sm\" class=\"align-top\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1968\" data-end=\"2259\"\u003e\n\u003ctr data-start=\"1968\" data-end=\"1999\"\u003e\n\u003ctd data-start=\"1968\" data-end=\"1984\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1984\" data-end=\"1999\"\u003e208V \/ 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2000\" data-end=\"2040\"\u003e\n\u003ctd data-start=\"2000\" data-end=\"2016\" data-col-size=\"sm\"\u003eInput Current\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2016\" data-end=\"2040\"\u003e30A (24A continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2041\" data-end=\"2068\"\u003e\n\u003ctd data-start=\"2041\" data-end=\"2058\" data-col-size=\"sm\"\u003ePower Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2058\" data-end=\"2068\"\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2069\" data-end=\"2097\"\u003e\n\u003ctd data-start=\"2069\" data-end=\"2082\" data-col-size=\"sm\"\u003eInput Plug\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2082\" data-end=\"2097\"\u003eNEMA L6-30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2098\" data-end=\"2121\"\u003e\n\u003ctd data-start=\"2098\" data-end=\"2112\" data-col-size=\"sm\"\u003eCord Length\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2112\" data-end=\"2121\"\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2122\" data-end=\"2160\"\u003e\n\u003ctd data-start=\"2122\" data-end=\"2132\" data-col-size=\"sm\"\u003eOutlets\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2132\" data-end=\"2160\"\u003e42 total (36×C13, 6×C19)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2161\" data-end=\"2192\"\u003e\n\u003ctd data-start=\"2161\" data-end=\"2172\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"2172\" data-end=\"2192\" data-col-size=\"sm\"\u003e0U Vertical Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2193\" data-end=\"2234\"\u003e\n\u003ctd data-start=\"2193\" data-end=\"2213\" data-col-size=\"sm\"\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2213\" data-end=\"2234\"\u003eEaton LX Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2235\" data-end=\"2259\"\u003e\n\u003ctd data-start=\"2235\" data-end=\"2243\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2243\" data-end=\"2259\"\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resilient Tec, LLC","offers":[{"title":"Default Title","offer_id":48348586541156,"sku":"PDUMNV30HV2LX","price":475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/PDUMNV30HV2LX.jpg?v=1777578587","url":"https:\/\/resilient-tec.com\/products\/pdumnv30hv2lx-tripp-lite-pdu-monitored-208-240v-30a-36-c13-6-c19-outlets-l6-30p-lx-interface-10-ft-cord-0urm-taa-new","provider":"Resilient Tec","version":"1.0","type":"link"}