{"title":"Cables \u0026 Optics for NVIDIA Quantum-2 QM9700 \/ QM9790","description":"\u003cp\u003eNDR InfiniBand cables and optics for the Quantum-2 QM9700 and QM9790 switches: finned-top 800G twin-port optics, switch-to-switch DACs, breakouts to 400G and NDR200 servers, and MPO-12\/APC fiber.\u003c\/p\u003e\u003cp\u003eSwitch ports take finned-top modules. See the \u003ca href=\"\/pages\/nvidia-hopper-h100-h200-interconnect-matrix\"\u003eH100 \/ H200 interconnect matrix\u003c\/a\u003e for link-by-link pairings.\u003c\/p\u003e","products":[{"product_id":"mfa7u10-h003-nvidia-mellanox-compatible-400g-osfp-to-2x200g-qsfp56-active-optical-breakout-cable-3m","title":"MFA7U10-H003 NVIDIA\/Mellanox Compatible 400G OSFP to 2x200G QSFP56 Active Optical Breakout Cable - 3m","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The MFA7U10-H003 NVIDIA\/Mellanox-compatible cable is a 3-meter active optical breakout (splitter) cable with one 400G twin-port OSFP end and two 200G QSFP56 ends, for linking an NDR-generation switch such as the Quantum-2 QM9700 to two 200G HDR ports, such as ConnectX-6 adapters. It is coded to work in NVIDIA equipment that calls for MFA7U10-H003. Resilient Tec sells it new, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003ch2\u003eNVIDIA\/Mellanox MFA7U10-H003 Compatible 400Gb\/s OSFP to 2x200Gb\/s QSFP56 Active Optical Breakout Cable - 3 Meters\u003c\/h2\u003e\n\u003cp\u003eThis third-party active optical breakout cable (AOC) is fully compatible with NVIDIA\/Mellanox MFA7U10-H003, providing a 400Gb\/s twin-port OSFP connection split to two 200Gb\/s QSFP56 ports over multimode fiber. Ideal for hybrid AI training clusters, HPC environments, and data centers bridging NDR 400G switches to HDR 200G adapters or nodes.\u003c\/p\u003e\n\u003cp\u003eUnlike passive DACs, this AOC offers longer reach, lighter weight, and better bend radius with integrated lasers for signal regeneration. Backed by our \u003cstrong\u003elifetime warranty\u003c\/strong\u003e and rigorous testing—save 70-90% vs. genuine OEM while enabling flexible, high-performance scaling.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Reach \u0026amp; Flexibility\u003c\/strong\u003e: Active optics for reliable performance up to 30m (series max)—far beyond passive copper—with low weight and EMI immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMassive Cost Savings\u003c\/strong\u003e: Affordable compatible AOC for mixed-generation AI\/HPC deployments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play\u003c\/strong\u003e: Hot-pluggable OSFP and QSFP56 connectors with pre-programmed EEPROM for seamless NVIDIA compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Latency\u003c\/strong\u003e: Optimized for InfiniBand HDR and 400GbE with integrated signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime Warranty\u003c\/strong\u003e: Fully tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse Cases\u003c\/strong\u003e: Fan-out in multi-node GPU clusters (e.g., connecting Quantum-2 NDR switches to ConnectX-6 HDR adapters).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate\u003c\/strong\u003e: 400Gbps total (HDR InfiniBand \/ 400GbE, split to 2x200Gbps, 8x50Gbps PAM4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors\u003c\/strong\u003e: 1x Twin-Port OSFP to 2x QSFP56\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 3 meters (10 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type\u003c\/strong\u003e: Active Optical Multimode Fiber (MMF, 850nm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: ~10-12W total (typical for AOC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IBTA HDR, OSFP\/QSFP56 MSA, CMIS compliant, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eProgrammed for full compatibility with NVIDIA\/Mellanox ecosystems and MSA-compliant platforms, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNVIDIA Quantum-2 QM9700 series switches (400G OSFP ports)\u003c\/li\u003e\n\u003cli\u003eNVIDIA ConnectX-6 adapters (200G QSFP56 ports)\u003c\/li\u003e\n\u003cli\u003eNVIDIA DGX A100\/H100 systems in hybrid setups\u003c\/li\u003e\n\u003cli\u003eOther OSFP\/QSFP56 platforms supporting HDR\/400GbE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed longer lengths (up to 30m), DAC alternatives, or bulk quotes? \u003cstrong\u003eContact us\u003c\/strong\u003e—we're your go-to for NVIDIA-compatible high-bandwidth AOCs in AI workloads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does each end plug into?\u003c\/strong\u003e\u003cbr\u003eThe OSFP end goes into a twin-port OSFP cage on the switch. Each QSFP56 end goes into a 200G HDR port, such as a ConnectX-6 adapter or an HDR switch port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAOC or DAC: which should I use?\u003c\/strong\u003e\u003cbr\u003eAn AOC is lighter, thinner and reaches farther than copper, which suits runs between racks. For short in-rack runs, a passive DAC costs less and draws no power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the fiber or change the length?\u003c\/strong\u003e\u003cbr\u003eNo. The optics and fiber are one sealed assembly, so the length is fixed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible cable or genuine NVIDIA: what is the difference?\u003c\/strong\u003e\u003cbr\u003eThis is a new third-party cable programmed (coded) to be recognized by NVIDIA\/Mellanox equipment that calls for this part number, at a fraction of the NVIDIA-branded price. Choose the genuine NVIDIA part only if your support contract or internal policy requires NVIDIA-branded parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch3\u003eYou Might Also Need\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/products\/mfs1s50-h005e-mellanox-200gb-s-qsfp56-active-optical-cable-5m\"\u003eNVIDIA MFS1S50-H005E, 200G to 2x100G HDR splitter AOC\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mcp7h50-h001r30-mellanox-compatible-200g-qsfp56-to-2x100g-qsfp56-passive-breakout-dac-cable-1m\"\u003eMCP7H50-H001R30 compatible, 200G to 2x100G QSFP56 breakout DAC\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/collections\/fiber\"\u003eAll fiber cables\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":47923345326180,"sku":"MFA7U10-H003","price":1345.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/mfa7u10-h003-nvidia-mellanox-compatible-400g-osfp-to-2x200g-qsfp56-active-optical-breakout-cable-3m_1_6d568f6d-2511-401d-bdf1-5972b2a5ed33.jpg?v=1793196699"},{"product_id":"nvidia-mellanox-mcp7y00-n002-compatible-800gb-s-osfp-to-2x400gb-s-osfp-passive-breakout-dac-cable-2m","title":"MCP7Y00-N002 NVIDIA\/Mellanox Compatible 800Gb\/s OSFP to 2x400Gb\/s OSFP Passive Breakout DAC Cable - 2m","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The MCP7Y00-N002 NVIDIA\/Mellanox-compatible cable is a 2-meter passive copper breakout (splitter) DAC that splits one 800G twin-port OSFP port into two 400G OSFP connections, for linking an NDR InfiniBand switch such as the Quantum-2 QM9700 to two 400G NDR ports, such as ConnectX-7 OSFP adapters, in the same or an adjacent rack. It is coded to work in NVIDIA equipment that calls for MCP7Y00-N002. Resilient Tec sells it new, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003ch2\u003eNVIDIA\/Mellanox MCP7Y00-N002 Compatible 800Gb\/s Twin-Port OSFP to 2x400Gb\/s OSFP Passive Breakout DAC Cable - 2 Meters\u003c\/h2\u003e\n\u003cp\u003eThis third-party passive breakout DAC cable is fully compatible with NVIDIA\/Mellanox MCP7Y00-N002, delivering an 800Gb\/s twin-port OSFP connection split to two independent 400Gb\/s OSFP ports. Engineered for InfiniBand NDR environments in cutting-edge AI supercomputers, HPC clusters, and hyperscale data centers.\u003c\/p\u003e\n\u003cp\u003eCompliant with MSA standards, it supports massive bandwidth (800G total, 2x400G PAM4) with ultra-low power and latency. Backed by our \u003cstrong\u003elifetime warranty\u003c\/strong\u003e and rigorous testing—save significantly vs. genuine OEM.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme Cost Savings\u003c\/strong\u003e: Affordable compatible for NDR deployments—scale AI superclusters without premium pricing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-Play\u003c\/strong\u003e: Hot-pluggable OSFP connectors (finned\/flat top variants) with pre-programmed EEPROM for seamless NVIDIA compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Low Power \u0026amp; Latency\u003c\/strong\u003e: Passive design (\u0026lt;0.5W total) for dense, efficient racks in power-hungry AI environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime Warranty\u003c\/strong\u003e: Fully tested.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse Cases\u003c\/strong\u003e: Splitter for multi-node GPU interconnects in NDR switches (e.g., QM9700 series), enabling 800G to 400G fan-out.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate\u003c\/strong\u003e: 800Gbps total (twin-port NDR InfiniBand, split to 2x400Gbps, PAM4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectors\u003c\/strong\u003e: 1x Twin-Port OSFP to 2x OSFP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 2 meters (6.6 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type\u003c\/strong\u003e: Passive Twinax Copper (typically 26-30AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Compliance\u003c\/strong\u003e: IBTA NDR, OSFP MSA, CMIS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eProgrammed for full compatibility with NVIDIA\/Mellanox NDR ecosystems and MSA platforms, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNVIDIA Quantum-2\/QM9700 NDR switches (800G ports)\u003c\/li\u003e\n\u003cli\u003eNVIDIA ConnectX-7\/BlueField-3 (400G ports)\u003c\/li\u003e\n\u003cli\u003eOther OSFP NDR platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed different lengths, flat-top variants, or volume quotes? \u003cstrong\u003eContact us\u003c\/strong\u003e—we source advanced NDR interconnects for AI leaders.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does each end plug into?\u003c\/strong\u003e\u003cbr\u003eThe single 800G end goes into a twin-port OSFP cage on the switch. Each 400G leg goes into a 400G OSFP port, such as a ConnectX-7 OSFP adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMCP7Y00-N002 or MCP7Y50-N001: which do I need?\u003c\/strong\u003e\u003cbr\u003eThe MCP7Y00-N002 splits one 800G switch port into two 400G links. The MCP7Y50-N001 splits it into four 200G links. Pick the one that matches the speed of the adapter ports on the other end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a DAC instead of optics?\u003c\/strong\u003e\u003cbr\u003eFor in-rack runs of a couple of meters, a passive DAC costs far less, draws no power and adds no optical latency. For longer runs between racks, use OSFP optics with fiber.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible cable or genuine NVIDIA: what is the difference?\u003c\/strong\u003e\u003cbr\u003eThis is a new third-party cable programmed (coded) to be recognized by NVIDIA\/Mellanox equipment that calls for this part number, at a fraction of the NVIDIA-branded price. Choose the genuine NVIDIA part only if your support contract or internal policy requires NVIDIA-branded parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch3\u003eYou Might Also Need\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/products\/mcp7y50-n001-mellanox-compatible-800g-osfp-to-4x200g-osfp-passive-breakout-dac-cable-1m\"\u003eMCP7Y50-N001 compatible, 800G OSFP to 4x200G OSFP breakout DAC\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400 compatible, 400G OSFP SR4 transceiver\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/collections\/dac-cables\"\u003eAll DAC cables\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":47923345424484,"sku":"MCP7Y00-N002","price":298.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/nvidia-mellanox-mcp7y00-n002-compatible-800gb-s-osfp-to-2x400gb-s-osfp-passive-breakout-dac-cable-2m_1_84da8497-cb24-4d0b-b25c-f918bdcdd56a.jpg?v=1793196718"},{"product_id":"mcp7y50-n001-mellanox-compatible-800g-osfp-to-4x200g-osfp-passive-breakout-dac-cable-1m","title":"MCP7Y50-N001 Compatible 800G OSFP to 4x200G OSFP Breakout DAC Cable - 1M | NVIDIA \/ Mellanox","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The MCP7Y50-N001 NVIDIA\/Mellanox-compatible cable is a 1-meter passive copper breakout (splitter) DAC that splits one 800G twin-port OSFP port into four 200G OSFP connections, for linking an NDR InfiniBand switch such as the Quantum-2 QM9700 to four 200G adapter ports in the same rack. It is coded to work in NVIDIA equipment that calls for MCP7Y50-N001. Resilient Tec sells it new, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003ch2\u003e800G OSFP to 4x200G OSFP Passive Breakout DAC Cable — Pre-Tested for NVIDIA \/ Mellanox\u003c\/h2\u003e\n\u003cp\u003eThe MCP7Y50-N001 is an \u003cstrong\u003e800G OSFP to 4x200G OSFP passive breakout DAC cable\u003c\/strong\u003e built for next-generation AI clusters, hyperscale data centers, and NDR InfiniBand fabrics. It delivers 800Gbps aggregate throughput by splitting a single 800G OSFP port into four independent 200G OSFP connections — with zero active components and zero power draw. Every unit is pre-programmed with EEPROM compatibility data and validated before shipment.\u003c\/p\u003e\n\u003ch3\u003eWill This Cable Work With My Platform?\u003c\/h3\u003e\n\u003cp\u003ePre-coded for seamless plug-and-play recognition on:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNVIDIA Quantum-2 \/ NDR InfiniBand switches\u003c\/strong\u003e (QM9700 series and compatible)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNVIDIA DGX \/ HGX systems\u003c\/strong\u003e and GPU-to-switch interconnects\u003c\/li\u003e\n\u003cli\u003eAny \u003cstrong\u003eOSFP MSA-compliant platform\u003c\/strong\u003e supporting NDR InfiniBand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot sure if this matches your exact setup? \u003cstrong\u003eContact us before you buy\u003c\/strong\u003e — our engineers will confirm compatibility for free.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e GPU-to-switch, switch-to-switch, and top-of-rack breakout connections in high-density AI and HPC environments.\u003c\/p\u003e\n\u003ch3\u003eDesigned for AI \u0026amp; HPC Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGPU cluster interconnects\u003c\/strong\u003e — spine-to-GPU or switch-to-DGX\/HGX connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNDR InfiniBand fabrics\u003c\/strong\u003e — 800G port breakout to 4x200G NDR endpoints\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAI training and inference at scale\u003c\/strong\u003e — maximize throughput, minimize latency between nodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHyperscale data center leaf-spine\u003c\/strong\u003e — high-density 800G port utilization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-throughput storage\u003c\/strong\u003e — NVMe over Fabric, GPUDirect Storage at 200G per lane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommon Mistakes This Cable Prevents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuying AOC when DAC is sufficient\u003c\/strong\u003e — for 1-meter runs, passive DAC is lower cost, lower latency, and zero power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM-locked cables causing recognition failures\u003c\/strong\u003e — our EEPROM pre-coding eliminates firmware rejection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWrong connector type\u003c\/strong\u003e — OSFP and QSFP-DD are not the same; always verify your port type before ordering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatency spikes from active components\u003c\/strong\u003e — passive DAC has no signal processing, no added jitter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e MCP7Y50-N001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e 800Gb\/s aggregate (4x200Gb\/s breakout)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e OSFP (800G) to 4x OSFP (200G each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1 Meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e Passive Direct Attach Copper (DAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Gauge:\u003c\/strong\u003e 30AWG Twinax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e Passive (0W)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e OSFP MSA compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e NDR InfiniBand (800Gb\/s)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Resilient Tec Guarantee\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e✅ Pre-programmed EEPROM — recognized immediately by compatible platforms\u003c\/li\u003e\n\u003cli\u003e✅ Compatibility-tested before every shipment\u003c\/li\u003e\n\u003cli\u003e✅ Lifetime warranty on all cables\u003c\/li\u003e\n\u003cli\u003e✅ Talk to a real engineer — not a chatbot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe don't just ship cables. We make sure they work in your environment.\u003c\/p\u003e\n\u003ch3\u003eRelated Products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G QSFP-DD to 4x100G QSFP28 Breakout DAC Cables\u003c\/li\u003e\n\u003cli\u003e200G QSFP56 to 2x100G QSFP56 Breakout DAC Cables\u003c\/li\u003e\n\u003cli\u003e800G OSFP Active Optical Cables (AOC) for longer runs\u003c\/li\u003e\n\u003cli\u003eOSFP Transceivers for 800G platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does each end plug into?\u003c\/strong\u003e\u003cbr\u003eThe single 800G end goes into a twin-port OSFP cage on the switch. Each of the four 200G legs goes into an OSFP port running at 200G, such as an NDR200 adapter port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMCP7Y50-N001 or MCP7Y00-N002: which do I need?\u003c\/strong\u003e\u003cbr\u003eThe MCP7Y50-N001 splits one 800G switch port into four 200G links. The MCP7Y00-N002 splits it into two 400G links. Pick the one that matches the speed of the adapter ports on the other end.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a DAC instead of optics?\u003c\/strong\u003e\u003cbr\u003eFor in-rack runs of a meter or two, a passive DAC costs far less, draws no power and adds no optical latency. For longer runs between racks, use OSFP optics with fiber.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible cable or genuine NVIDIA: what is the difference?\u003c\/strong\u003e\u003cbr\u003eThis is a new third-party cable programmed (coded) to be recognized by NVIDIA\/Mellanox equipment that calls for this part number, at a fraction of the NVIDIA-branded price. Choose the genuine NVIDIA part only if your support contract or internal policy requires NVIDIA-branded parts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch3\u003eYou Might Also Need\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/products\/nvidia-mellanox-mcp7y00-n002-compatible-800gb-s-osfp-to-2x400gb-s-osfp-passive-breakout-dac-cable-2m\"\u003eMCP7Y00-N002 compatible, 800G OSFP to 2x400G OSFP breakout DAC\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS compatible, 800G OSFP SR8 twin-port transceiver\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/collections\/dac-cables\"\u003eAll DAC cables\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":48440381079652,"sku":"MCP7Y50-N001","price":384.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/mcp7y50-n001-mellanox-compatible-800g-osfp-to-4x200g-osfp-passive-breakout-dac-cable-1m_1.jpg?v=1793145847"},{"product_id":"mcp4y10-n001-800g-twin-port-osfp-passive-dac-cable-1m-finned-top-quantum-2","title":"MCP4Y10-N001 Compatible 800G Twin-Port OSFP Passive DAC Cable, 1m, Finned Top – Quantum-2 Switch-to-Switch","description":"\u003cp\u003e\u003cstrong\u003eTwin-port 800G OSFP passive DAC for NVIDIA Quantum-2 switch-to-switch links. Finned top on both ends.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart number:\u003c\/strong\u003e MCP4Y10-N001 (NVIDIA \/ Mellanox LinkX compatible)\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e 800Gb\/s twin-port OSFP to twin-port OSFP passive direct attach copper cable, 2×400G NDR InfiniBand, 1 m (3.3 ft), 30AWG\u003c\/p\u003e\n\u003cp\u003eThe MCP4Y10-N001 links two NVIDIA Quantum-2 switch ports at 800Gb\/s. Each OSFP end carries two independent 400G NDR links (8 × 100G-PAM4 lanes), so one cable joins two switch cages and carries two 400G ports' worth of traffic. Both ends have the \u003cstrong\u003efinned-top\u003c\/strong\u003e heat sink that air-cooled Quantum-2 and Spectrum-4 switch cages require.\u003c\/p\u003e\n\u003ch2\u003eWhere It Fits, and Where It Does Not\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYes:\u003c\/strong\u003e Quantum-2 QM9700 \/ QM9790 InfiniBand switch to switch (leaf to spine, inter-switch links) inside a rack or to the next rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYes:\u003c\/strong\u003e Spectrum-4 800GbE switch to switch, where the twin-port OSFP cages are finned-top as well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo:\u003c\/strong\u003e DGX H100 \/ DGX H200 or ConnectX-7 adapters. Those cages are flat-top and their ports are 400G, so a finned-top twin-port cable will not seat. To reach servers from the switch, use the \u003ca href=\"\/products\/nvidia-mellanox-mcp7y00-n002-compatible-800gb-s-osfp-to-2x400gb-s-osfp-passive-breakout-dac-cable-2m\"\u003eMCP7Y00-N002 800G → 2× 400G breakout DAC\u003c\/a\u003e, or flat-top optics such as the \u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eMCP4Y10-N001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData rate\u003c\/td\u003e\n\u003ctd\u003e800Gb\/s (2 × 400G NDR InfiniBand or 800GbE), 8 × 100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop style\u003c\/td\u003e\n\u003ctd\u003eFinned top, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003ctd\u003ePassive direct attach copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire gauge\u003c\/td\u003e\n\u003ctd\u003e30AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e1 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHosts\u003c\/td\u003e\n\u003ctd\u003eNVIDIA Quantum-2 QM9700 \/ QM9790, Spectrum-4 twin-port OSFP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eGood to Know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNeed 2 m instead? See the \u003ca href=\"\/products\/mcp4y10-n002-800g-twin-port-osfp-passive-dac-cable-2m-finned-top-quantum-2\"\u003eMCP4Y10-N002\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBeyond 2 m, use a finned-top \u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS\u003c\/a\u003e at each switch with MPO-12\/APC OM4 trunks.\u003c\/li\u003e\n\u003cli\u003ePassive copper draws almost no power and adds the least latency of any switch-to-switch option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Guides\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/nvidia-hopper-h100-h200-interconnect-matrix\"\u003eH100 \/ H200 interconnect matrix\u003c\/a\u003e: every link in a Hopper cluster, with the right cable for each.\u003cbr\u003e\u003ca href=\"\/blogs\/news\/osfp-flat-top-vs-finned-top-which-module\"\u003eOSFP flat-top vs finned-top: which do you need?\u003c\/a\u003e\u003c\/p\u003e","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":48896023232612,"sku":"MCP4Y10-N001","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/01_main_v2.jpg?v=1794246234"},{"product_id":"mcp4y10-n002-800g-twin-port-osfp-passive-dac-cable-2m-finned-top-quantum-2","title":"MCP4Y10-N002 Compatible 800G Twin-Port OSFP Passive DAC Cable, 2m, Finned Top – Quantum-2 Switch-to-Switch","description":"\u003cp\u003e\u003cstrong\u003eTwin-port 800G OSFP passive DAC for NVIDIA Quantum-2 switch-to-switch links. Finned top on both ends.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart number:\u003c\/strong\u003e MCP4Y10-N002 (NVIDIA \/ Mellanox LinkX compatible)\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e 800Gb\/s twin-port OSFP to twin-port OSFP passive direct attach copper cable, 2×400G NDR InfiniBand, 2 m (6.6 ft), 28AWG\u003c\/p\u003e\n\u003cp\u003eThe MCP4Y10-N002 links two NVIDIA Quantum-2 switch ports at 800Gb\/s. Each OSFP end carries two independent 400G NDR links (8 × 100G-PAM4 lanes), so one cable joins two switch cages and carries two 400G ports' worth of traffic. Both ends have the \u003cstrong\u003efinned-top\u003c\/strong\u003e heat sink that air-cooled Quantum-2 and Spectrum-4 switch cages require.\u003c\/p\u003e\n\u003ch2\u003eWhere It Fits, and Where It Does Not\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYes:\u003c\/strong\u003e Quantum-2 QM9700 \/ QM9790 InfiniBand switch to switch (leaf to spine, inter-switch links) inside a rack or to the next rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYes:\u003c\/strong\u003e Spectrum-4 800GbE switch to switch, where the twin-port OSFP cages are finned-top as well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo:\u003c\/strong\u003e DGX H100 \/ DGX H200 or ConnectX-7 adapters. Those cages are flat-top and their ports are 400G, so a finned-top twin-port cable will not seat. To reach servers from the switch, use the \u003ca href=\"\/products\/nvidia-mellanox-mcp7y00-n002-compatible-800gb-s-osfp-to-2x400gb-s-osfp-passive-breakout-dac-cable-2m\"\u003eMCP7Y00-N002 800G → 2× 400G breakout DAC\u003c\/a\u003e, or flat-top optics such as the \u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eMCP4Y10-N002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData rate\u003c\/td\u003e\n\u003ctd\u003e800Gb\/s (2 × 400G NDR InfiniBand or 800GbE), 8 × 100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTop style\u003c\/td\u003e\n\u003ctd\u003eFinned top, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003ctd\u003ePassive direct attach copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire gauge\u003c\/td\u003e\n\u003ctd\u003e28AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e2 m (6.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHosts\u003c\/td\u003e\n\u003ctd\u003eNVIDIA Quantum-2 QM9700 \/ QM9790, Spectrum-4 twin-port OSFP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eGood to Know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNeed 1 m instead? See the \u003ca href=\"\/products\/mcp4y10-n001-800g-twin-port-osfp-passive-dac-cable-1m-finned-top-quantum-2\"\u003eMCP4Y10-N001\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eBeyond 2 m, use a finned-top \u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS\u003c\/a\u003e at each switch with MPO-12\/APC OM4 trunks.\u003c\/li\u003e\n\u003cli\u003ePassive copper draws almost no power and adds the least latency of any switch-to-switch option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Guides\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/nvidia-hopper-h100-h200-interconnect-matrix\"\u003eH100 \/ H200 interconnect matrix\u003c\/a\u003e: every link in a Hopper cluster, with the right cable for each.\u003cbr\u003e\u003ca href=\"\/blogs\/news\/osfp-flat-top-vs-finned-top-which-module\"\u003eOSFP flat-top vs finned-top: which do you need?\u003c\/a\u003e\u003c\/p\u003e","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":48916337655908,"sku":"MCP4Y10-N002","price":243.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/01_main_v2_b10347f6-1af8-45ca-9079-7351844a66a6.jpg?v=1794246246"},{"product_id":"nvidia-mfp7e10-n005-5m-passive-multimode-fiber-cable-mpo-12-apc-to-mpo-12-apc","title":"NVIDIA MFP7E10-N005 5M Passive Multimode Fiber Cable — MPO-12\/APC to MPO-12\/APC","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e The NVIDIA MFP7E10-N005 (980-9I73V-000005) is a genuine NVIDIA 5-meter passive multimode fiber cable with MPO-12\/APC connectors on both ends, used to link NDR-generation 400G\/800G multimode optics in InfiniBand and Ethernet fabrics. Resilient Tec sells it new and factory-original, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenuine NVIDIA MFP7E10-N005 — 5 m Passive Multimode Fiber Cable, MPO-12\/APC to MPO-12\/APC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MFP7E10-N005 (NVIDIA)\u003cbr\u003e\u003cstrong\u003eNVIDIA Product Number:\u003c\/strong\u003e 980-9I73V-000005\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e Genuine NVIDIA 5-meter passive multimode fiber cable with MPO-12\/APC connectors on both ends, built for NVIDIA NDR \/ high-speed data-center networking. New, factory-original — not a compatible or aftermarket substitute.\u003c\/p\u003e\n\u003cp\u003eResilient Tec is offering genuine NVIDIA MFP7E10-N005 passive multimode fiber cables, factory-new and ready to ship. The MFP7E10-N005 is NVIDIA's 5-meter passive fiber cable featuring MPO-12\/APC connectors on both ends, and NVIDIA identifies the corresponding NVIDIA product number as 980-9I73V-000005.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003ctd\u003eValue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMFP7E10-N005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVIDIA Product Number\u003c\/td\u003e\n\u003ctd\u003e980-9I73V-000005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive multimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e5 meters \/ 16.4 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector A\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector B\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMultimode fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eNVIDIA NDR \/ high-speed data-center networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew, original NVIDIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy Original NVIDIA?\u003c\/h2\u003e\n\u003cp\u003eThere are many third-party cables advertised as \"MFP7E10-N005 compatible.\" This listing is for the original NVIDIA part, not a compatible or aftermarket substitute. For data-center deployments, using the exact manufacturer-specified component can simplify procurement, standardization and replacement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIdeal For\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNVIDIA NDR InfiniBand environments\u003c\/li\u003e\n\u003cli\u003eHigh-performance computing (HPC)\u003c\/li\u003e\n\u003cli\u003eAI\/ML infrastructure\u003c\/li\u003e\n\u003cli\u003eGPU clusters\u003c\/li\u003e\n\u003cli\u003eHigh-speed data-center networking\u003c\/li\u003e\n\u003cli\u003eLeaf\/spine architectures\u003c\/li\u003e\n\u003cli\u003eData-center expansion and replacement inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eVolume Pricing Available\u003c\/h2\u003e\n\u003cp\u003eNeed more than one? We have bulk inventory available and can offer quantity pricing for integrators, resellers, data-center operators and enterprise deployments. Contact Resilient Tec for pricing on larger quantities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MFP7E10-N005 — Original NVIDIA equipment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this the original NVIDIA cable or a compatible?\u003c\/strong\u003e\u003cbr\u003eOriginal NVIDIA, part MFP7E10-N005, NVIDIA product number 980-9I73V-000005. It is not a third-party compatible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich optics does it connect?\u003c\/strong\u003e\u003cbr\u003eNDR-generation multimode optics with MPO-12\/APC ports, such as the 400G OSFP SR4 (MMA4Z00-NS400), 400G QSFP112 SR4 (MMA1Z00-NS400) and each port of the 800G twin-port SR8 (MMA4Z00-NS).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it work with 100G or 200G SR4 optics?\u003c\/strong\u003e\u003cbr\u003eUsually not. Those generations use MPO UPC (flat) connectors, and APC and UPC endfaces should not be mated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch3\u003eYou Might Also Need\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400 compatible 400G OSFP SR4\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400 compatible 400G QSFP112 SR4\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS compatible 800G OSFP SR8\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/products\/mpo-12-apc-om4-multimode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-ndr-400g-800g-optics\"\u003eType B OM4 MPO-12\/APC trunk, 1–20 m\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/collections\/fiber\"\u003eAll fiber cables\u003c\/a\u003e\u003c\/p\u003e\n","brand":"NVIDIA","offers":[{"title":"Default Title","offer_id":48972814549092,"sku":"MFP7E10-N005","price":44.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/nvidia-mfp7e10-n005-mpo-12-apc-fiber-5m-1.jpg?v=1792761280"},{"product_id":"mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2","title":"NVIDIA MMA4Z00-NS Compatible 800G OSFP SR8 Finned-Top (IHS) Twin-Port Transceiver — Dual MPO-12\/APC, for Quantum-2 QM9700\/QM9790","description":"\u003cp\u003e\u003cstrong\u003eFinned-Top (IHS) — the switch-side module, not the NIC-side module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNVIDIA MMA4Z00-NS compatible — 800G OSFP SR8 twin-port, 850nm multimode, breaks out to 2 x 400G\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"border-left: 3px solid #1e8f5e; background: #f7f8fa; padding: 10px 14px; margin: 14px 0;\"\u003e→ \u003cstrong\u003e\u003ca href=\"\/pages\/nvidia-osfp-transceiver-part-number-crosswalk\"\u003eNVIDIA OSFP part-number crosswalk\u003c\/a\u003e\u003c\/strong\u003e — Mellanox MMA\/MMS numbers mapped to the new NVIDIA 980- numbers, with form factor, optics and the correct part for each end of the link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Equivalent:\u003c\/strong\u003e NVIDIA \/ Mellanox MMA4Z00-NS\u003cbr\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e Twin-port OSFP SR8 optical transceiver, 800Gb\/s, finned-top \/ Integrated Heat Sink (IHS), dual MPO-12\/APC, multimode\u003c\/p\u003e\n\u003cp\u003eThis is the \u003cstrong\u003efinned-top\u003c\/strong\u003e module — the one that goes in the switch, not the server. Air-cooled Quantum-2 switch ports have no heatsink of their own, so the module has to carry its own fins. Put this in a ConnectX-7 and it will not seat. Put a flat-top module in an air-cooled switch and it seats fine, looks like it worked, and has no cooling path at all.\u003c\/p\u003e\n\u003cp\u003eNVIDIA now calls this form factor \u003cstrong\u003eIHS\u003c\/strong\u003e, for \u003cstrong\u003eIntegrated Heat Sink\u003c\/strong\u003e — the fins are integrated into the module's own metal top. Older documentation and existing BOMs still say \"finned-top.\" Same part.\u003c\/p\u003e\n\u003cp\u003eIt is a twin-port module: \u003cstrong\u003e800G total, presenting as 2 x 400G.\u003c\/strong\u003e One of these serves two servers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhich One Do I Need?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eGoing into\u003c\/th\u003e\n\u003cth\u003eYou need\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir-cooled Quantum-2 switch (QM9700 \/ QM9790) or Spectrum-4\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFinned-Top (IHS)\u003c\/strong\u003e — this product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectX-7 \/ ConnectX-8 single-port OSFP NIC\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eFlat-Top (RHS) — 400G single-port module\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlueField-3 DPU, or a ConnectX-7 in its QSFP112 form\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400 — QSFP112, not OSFP\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThe fins are either on the module or on the equipment. Never both, never neither.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnd OSFP does not go in a BlueField-3 at all.\u003c\/strong\u003e NVIDIA states that BlueField-3 adapters accept QSFP112 devices only, and that OSFP is not for use in BlueField-3 DPUs. Neither this module nor the 400G flat-top will seat in one — that port needs the \u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400\u003c\/a\u003e, the same optics in a QSFP112 shell, on the same MPO-12\/APC fiber. A twin-port module in the switch can feed QSFP112 adapters and OSFP adapters in any combination — the fiber is identical, only the far-end shell changes.\u003c\/p\u003e\n\u003cp\u003eThe canonical topology: one twin-port finned module in the switch → two MPO-12\/APC patch cords → two flat-top modules in two ConnectX-7 servers. When you are sizing an order, that is the ratio — \u003cstrong\u003efor every two server ports, one switch module.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Equivalent\u003c\/td\u003e\n\u003ctd\u003eNVIDIA \/ Mellanox MMA4Z00-NS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP, Finned-Top (Integrated Heat Sink \/ IHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e800Gb\/s — 8 x 106.125Gb\/s PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface\u003c\/td\u003e\n\u003ctd\u003eSR8 (presents as 2 x SR4), 850nm, multimode (MMF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MPO\/MTP-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReach\u003c\/td\u003e\n\u003ctd\u003e30m OM3 \/ 50m OM4 — see note below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreakout\u003c\/td\u003e\n\u003ctd\u003e1 x 800G, or 2 x 400G to two flat-top modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Platforms\u003c\/td\u003e\n\u003ctd\u003eQuantum-2 air-cooled InfiniBand switches (QM9700, QM9790)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter-side counterparts\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400\u003c\/a\u003e (OSFP) or \u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400\u003c\/a\u003e (QSFP112)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDOM \/ DDM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoding\u003c\/td\u003e\n\u003ctd\u003eCoded specifically for NVIDIA \/ Mellanox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, Class 1 laser, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eNote on Reach: Why You'll See Both 50m and 100m\u003c\/h2\u003e\n\u003cp\u003eNVIDIA specifies \u003cstrong\u003e50m over OM4\u003c\/strong\u003e, and that is the figure to design against in an InfiniBand fabric. The optics are built to the SR MSA, which permits up to 100m over OM4 — both numbers are correct, they answer different questions. The standard describes what the optics \u003cem\u003ecan\u003c\/em\u003e do under ideal conditions; NVIDIA's number is what they will \u003cem\u003esupport\u003c\/em\u003e. NVIDIA's own documentation for this twin-port family describes straight multimode crossover cables up to 100m and splitter cables up to 50m, which is the same budget described from the cable's end rather than the module's.\u003c\/p\u003e\n\u003cp\u003eUsable reach past 50m depends on fiber grade and how many MPO matings sit in the path, because every additional mating costs optical budget. \u003cstrong\u003eDesign to 50m for NVIDIA support parity.\u003c\/strong\u003e Planning a longer run? \u003ca href=\"\/pages\/request-a-quote\"\u003eTalk to us first\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eGood to Know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThis module will not seat in a ConnectX-7 OSFP port. The port cage carries its own riding heatsink and there is no clearance for fins.\u003c\/li\u003e\n\u003cli\u003e800G is not an upgrade at the server end — the ConnectX-7 OSFP port is a 400G port. If you are buying for a NIC, you want the \u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003e400G flat-top module\u003c\/a\u003e, or the \u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eQSFP112 version\u003c\/a\u003e if the adapter is a BlueField-3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePopulating DGX H100 front cages?\u003c\/strong\u003e Those are twin-port \u003cem\u003eflat-top\u003c\/em\u003e cages. NVIDIA's documentation for this family specifies the flat-top 800G variant, \u003cstrong\u003eMMA4Z00-NS-FLT\u003c\/strong\u003e, for the DGX H100 — the finned part is for Quantum-2 and Spectrum-4 switches, where airflow is reduced. The same flat-top logic applies to liquid-cooled deployments, where a cold plate contacts a flat surface. We do not stock MMA4Z00-NS-FLT — but that is the part number to specify, and if someone has quoted you the finned part for a DGX front cage, that quote is wrong. On single-mode fiber, the flat-top \u003ca href=\"\/products\/mms4x00-nm-compatible-800g-osfp-2xdr4-twin-port-transceiver-quantum-2?variant=49280963313764\"\u003eMMS4X00-NM-FLT\u003c\/a\u003e compatible (800G 2×DR4, 500 m, coded for NVIDIA) is in stock at $999.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMMS4X00-NM\u003c\/strong\u003e and \u003cstrong\u003eMMS4X00-NS\u003c\/strong\u003e are the 800G single-mode DR8 variants. The MMA \/ MMS prefix is the tell: MMA is multimode, MMS is single-mode.\u003c\/li\u003e\n\u003cli\u003eRunning single-mode? This is not your module. Tell us what the fiber plant is and we will point you at the right part rather than sell you this one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick Checklist — Is This the Right Module?\u003c\/h2\u003e\n\u003cp\u003eYou are populating a port on an air-cooled Quantum-2 InfiniBand switch (QM9700 or QM9790). The port has no heatsink of its own. Your fiber plant is multimode (OM3 or OM4) with MPO-12\/APC connectors. Your runs are 50m or shorter. You want one switch port to feed two 400G server ports.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp style=\"border-left: 3px solid #1e8f5e; background: #f7f8fa; padding: 10px 14px; margin: 14px 0;\"\u003e\u003cstrong\u003eIn stock at Resilient Tec · Additional units ship on a 7–10 day lead time.\u003c\/strong\u003e\u003cbr\u003eBuilding a cluster? Tell us how many ports you are populating and we will quote the switch-side and server-side modules together. \u003ca href=\"\/pages\/request-a-quote\"\u003e\u003cstrong\u003eRequest a quote →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e lifetime, \u003ca href=\"\/pages\/lifetime-warranty\"\u003ebacked by Resilient Tec\u003c\/a\u003e — not a manufacturer term. When a module fails you reach a named seller in Knoxville, Tennessee, not a ticket queue.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eYou Might Also Need\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003e400G OSFP SR4 Flat-Top (RHS) transceiver\u003c\/a\u003e — the server-side pair. Order two per module of these.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400 — 400G QSFP112 SR4\u003c\/a\u003e — the adapter-side module when the far end is a BlueField-3 or a ConnectX-7 QSFP112\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mpo-12-apc-om4-multimode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-ndr-400g-800g-optics\"\u003eMPO-12\/APC OM4 multimode trunk cable, Type B, female-to-female\u003c\/a\u003e — two per twin-port module, $59.00 to $139.00\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/mpo-12-apc-1-2-splitter-cable-custom-build\"\u003eMPO-12\/APC 1:2 splitter cables\u003c\/a\u003e — built to order, when one twin-port switch port feeds four adapters at NDR200\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/blogs\/news\/osfp-dac-cables-what-they-are-when-to-use-one\"\u003eOSFP DAC cables\u003c\/a\u003e — when the run is short enough that copper beats optics\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/product-guides\"\u003eProduct guides\u003c\/a\u003e — structured cabling, switches and the rest of the rack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Guides\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/osfp-flat-top-vs-finned-top-which-module\"\u003eFlat-Top or Finned-Top OSFP? How to Tell Which Module Your ConnectX-7 Actually Needs\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/mpo-12-apc-vs-upc-ndr-fiber-guide\"\u003eMPO-12\/APC vs UPC: Why Your Existing Fiber Won't Work With NDR Optics\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/nvidia-osfp-transceiver-part-number-crosswalk\"\u003eNVIDIA OSFP Part-Number Crosswalk: Mellanox MMA\/MMS to NVIDIA 980- Numbers\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/news\/osfp-vs-qsfp-dd-gpu-clusters\"\u003eOSFP vs. QSFP-DD: A Practical Breakdown for GPU Clusters\u003c\/a\u003e\u003c\/p\u003e","brand":"Resilient Tec","offers":[{"title":"Default Title","offer_id":49073639555172,"sku":"MMA4Z00-NS","price":759.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/IMG_5122.jpg?v=1788898588"},{"product_id":"mpo-12-apc-om4-multimode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-ndr-400g-800g-optics","title":"MPO-12\/APC OM4 Multimode Trunk Cable, Type B, Female-to-Female — for NVIDIA NDR 400G\/800G Optics","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e This is an MPO-12\/APC OM4 multimode trunk cable, Type B crossover, female\/unpinned on both ends, with all 12 fibers terminated and keyed up to down for APC. It is built for NVIDIA NDR-generation 400G\/800G multimode optics (SR4\/SR8). Available in 1, 3, 5, 10, 15 and 20 m. Resilient Tec sells it new, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNDR optics require APC. The UPC cords from your 100G or 200G fabric will not mate with them.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an MPO-12 trunk cable with \u003cstrong\u003eangle-polished (APC) endfaces\u003c\/strong\u003e, built to the polarity and gender NVIDIA NDR-generation optics actually need: \u003cstrong\u003eType B crossover, female\/unpinned on both ends, all 12 fibers terminated.\u003c\/strong\u003e OM4 50\/125 multimode, aqua jacket, green connector housings, OFNP plenum rated.\u003c\/p\u003e\n\u003cp\u003eIf you are populating an \u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400\u003c\/a\u003e, an \u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400\u003c\/a\u003e or an \u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS\u003c\/a\u003e, this is the cable.\u003c\/p\u003e\n\n\u003ch2\u003eAPC vs UPC — read this before you order\u003c\/h2\u003e\n\u003cp\u003eAn APC connector has an \u003cstrong\u003e8° angled endface\u003c\/strong\u003e. A UPC connector is flat. They cannot mate. Put them together and you get an air gap, an unusable return loss figure, and a link that either never comes up or comes up and drifts.\u003c\/p\u003e\n\u003cp\u003eThe 100G (4×25G NRZ) and 200G (4×50G PAM4) generations were overwhelmingly \u003cstrong\u003eUPC\u003c\/strong\u003e. NDR 400G and 800G moved to \u003cstrong\u003eAPC\u003c\/strong\u003e. A customer upgrading an existing fabric does not carry their patch cords forward. This is the most common ordering mistake in an NDR upgrade, and most supplier pages never mention it. \u003ca href=\"\/blogs\/news\/mpo-12-apc-vs-upc-ndr-fiber-guide\"\u003eThe full MPO-12\/APC vs UPC guide is here.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to tell at a glance:\u003c\/strong\u003e a green connector housing means APC — NVIDIA's own module documentation describes the MPO-12\/APC interface as having a green plastic shell. The \u003cem\u003ejacket\u003c\/em\u003e color tells you the fiber type — aqua is OM3\/OM4 — not the endface. Two different things, easy to conflate, and jacket colors vary between manufacturers. The connector housing is the reliable answer.\u003c\/p\u003e\n\n\u003ch2\u003eKey orientation: key-up to key-down\u003c\/h2\u003e\n\u003cp\u003eThe industry shorthand \"Type B means key-up to key-up\" is a \u003cstrong\u003eUPC\u003c\/strong\u003e rule, and it does not transfer to APC. Two 8° angled endfaces have to be complementary to seat, so an APC Type B assembly mates \u003cstrong\u003ekey-up to key-down\u003c\/strong\u003e — Modified Method B, a Type B cable through Type A (key-up\/key-down) adapters.\u003c\/p\u003e\n\u003cp\u003eThis cable is built key-up to key-down, confirmed in writing by the manufacturer. Worth checking whatever else you are buying: it is not unusual to find a part listed as APC and \"female key-up to female key-up\" on the same page, which cannot physically mate.\u003c\/p\u003e\n\n\u003ch2\u003eFully terminated 12-fiber — and why that is a feature\u003c\/h2\u003e\n\u003cp\u003eAll twelve positions are terminated in a Type B crossover: position 1 lands on position 12, 2 on 11, and so on across the connector.\u003c\/p\u003e\n\u003cp\u003eAn SR4 module uses four lanes in each direction. NVIDIA's own MFP7E10 multimode cable is built with \u003cstrong\u003eeight\u003c\/strong\u003e fibers populated — positions 1–4 and 9–12, with 5–8 left unconnected — because that is all an SR4 link needs. Ours terminates all twelve. In an SR4 link the two are interchangeable: the module's four transmit positions land on the far end's four receive positions either way, and the extra pairs simply carry no traffic.\u003c\/p\u003e\n\u003cp\u003eThe difference shows up later. A fully terminated assembly can be re-tested end to end, can carry a different lane map if you repurpose it, and does not leave you guessing which positions were populated when a link goes marginal two years from now.\u003c\/p\u003e\n\n\u003ch2\u003eWhich one do I need?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModule\u003c\/th\u003e\n\u003cth\u003ePorts\u003c\/th\u003e\n\u003cth\u003eCable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMA4Z00-NS400\u003c\/a\u003e — 400G OSFP SR4, flat-top (ConnectX-7 \/ ConnectX-8, NIC side)\u003c\/td\u003e\n\u003ctd\u003e1× MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eThis cable\u003c\/strong\u003e — one per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400\u003c\/a\u003e — 400G QSFP112 SR4 (ConnectX-7 QSFP112 and BlueField-3, NIC side)\u003c\/td\u003e\n\u003ctd\u003e1× MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eThis cable\u003c\/strong\u003e — one per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003eMMA4Z00-NS\u003c\/a\u003e — 800G OSFP 2×SR4, twin-port (Quantum-2 \/ Spectrum-4, switch side)\u003c\/td\u003e\n\u003ctd\u003e2× MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eThis cable\u003c\/strong\u003e — two per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-mode DR-class modules\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003eUse the \u003cstrong\u003eOS2 single-mode\u003c\/strong\u003e version instead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOSFP does not go in a BlueField-3.\u003c\/strong\u003e NVIDIA states that BlueField-3 adapters accept QSFP112 devices only, so a BlueField-3 takes the \u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003eMMA1Z00-NS400\u003c\/a\u003e, not the OSFP MMA4Z00-NS400. The fiber is the same either way — this cable serves both.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwin-port rule:\u003c\/strong\u003e both ports on a twin-port module must run the same fiber type. Do not mix a straight cable in one port and something else in the other.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMPO-12 \/ APC, 8° angled endface, green housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGender\u003c\/td\u003e\n\u003ctd\u003eFemale \/ unpinned, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber count\u003c\/td\u003e\n\u003ctd\u003e12 positions, all 12 terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eType B crossover (position 1 to position 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey orientation\u003c\/td\u003e\n\u003ctd\u003eKey-up to key-down (Modified Method B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber\u003c\/td\u003e\n\u003ctd\u003eOM4 50\/125 multimode, aqua jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsertion loss\u003c\/td\u003e\n\u003ctd\u003e≤0.35 dB per connector, low-loss grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket rating\u003c\/td\u003e\n\u003ctd\u003eOFNP (plenum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLengths\u003c\/td\u003e\n\u003ctd\u003e1, 3, 5, 10, 15, 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003ePricing by length\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-01M\u003c\/td\u003e\n\u003ctd\u003e$59.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-03M\u003c\/td\u003e\n\u003ctd\u003e$69.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-05M\u003c\/td\u003e\n\u003ctd\u003e$79.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-10M\u003c\/td\u003e\n\u003ctd\u003e$99.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-15M\u003c\/td\u003e\n\u003ctd\u003e$119.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OM4-20M\u003c\/td\u003e\n\u003ctd\u003e$139.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eVolume:\u003c\/strong\u003e 10 or more of any one length, 10% off. 25 or more, 18% off. Quoted at checkout or on a pod quote.\u003c\/p\u003e\n\n\u003ch2\u003eGood to know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFemale\/unpinned is correct.\u003c\/strong\u003e NVIDIA's SR4 and SR8 modules carry the alignment pins; the fiber connector carries the matching holes. Pinned MPO connectors belong on permanent-link backbone cabling that lands in a patch panel, not on the cable that plugs into an optic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOM4 at every length.\u003c\/strong\u003e NVIDIA's own MFP7E10 assemblies are specified OM3 at 30 m and under, OM4 only above 30 m. Every length here is OM4, including the 1 m — more margin in the link than the OEM part gives you at the same distance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFNP, not riser.\u003c\/strong\u003e This cable is plenum-rated. NVIDIA's MFP7E10 assemblies are specified LSZH-OFNR — riser. If your run crosses a plenum air-handling space, OFNR is not code-compliant and OFNP is.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe connectors are the loss budget.\u003c\/strong\u003e At data-center distances the fiber itself contributes almost nothing. Nearly all of your loss sits in the mated pairs, which is why low-loss grade matters more here than length does.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDerate the reach.\u003c\/strong\u003e The 50 m OM4 figure on NVIDIA's SR4 modules — 30 m on OM3 — already assumes patch panels in the link, which is four connector junctions. It is not 50 m of clean fiber with headroom on top. More hops means less usable distance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eQuick checklist — is this the right cable?\u003c\/h2\u003e\n\u003cp\u003eYour optics are NDR-generation and take MPO-12\/\u003cstrong\u003eAPC\u003c\/strong\u003e. Your fiber plant is \u003cstrong\u003emultimode\u003c\/strong\u003e (OM3\/OM4). You need a \u003cstrong\u003estraight\u003c\/strong\u003e cable, not a \u003ca href=\"\/pages\/mpo-12-apc-1-2-splitter-cable-custom-build\"\u003e1:2 splitter\u003c\/a\u003e. Your run still fits its loss budget with four connector junctions in the path.\u003c\/p\u003e\n\u003cp\u003eIf you do need a splitter — one twin-port 800G switch port feeding four adapters at NDR200 — \u003ca href=\"\/pages\/mpo-12-apc-1-2-splitter-cable-custom-build\"\u003ewe build those to order\u003c\/a\u003e in multimode or single-mode, to your leg lengths.\u003c\/p\u003e\n\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIn stock at Resilient Tec.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipped from Knoxville, Tennessee. Free standard shipping on all US orders, no minimum. Populating a pod? Tell us your node count and module part numbers and we will quote the cables and the optics together. \u003ca href=\"\/pages\/request-a-quote\"\u003eRequest a quote →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e lifetime, \u003ca href=\"\/pages\/lifetime-warranty\"\u003ebacked by Resilient Tec\u003c\/a\u003e — not a manufacturer term. When something fails you reach a named seller in Knoxville, not a ticket queue.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I reuse my 100G\/200G MPO cords with NDR optics?\u003c\/strong\u003e\u003cbr\u003eNo. 100G and 200G optics were mostly MPO UPC; NDR optics are MPO APC. The endfaces cannot mate, so upgrades need new APC cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Type B, female to female?\u003c\/strong\u003e\u003cbr\u003eNDR transceivers have pinned (male) MPO ports, so the cable must be unpinned (female) on both ends, and a point-to-point SR4\/SR8 link needs Type B crossover polarity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch2\u003eYou might also need\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma4z00-ns400-compatible-400g-osfp-sr4-flat-top-rhs-transceiver-connectx-7\"\u003e400G OSFP SR4 (MMA4Z00-NS400)\u003c\/a\u003e — the NIC-side module this cable plugs into\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma1z00-ns400-compatible-400g-qsfp112-sr4-transceiver-bluefield-3-connectx-7\"\u003e400G QSFP112 SR4 (MMA1Z00-NS400)\u003c\/a\u003e — the same optics for BlueField-3 and ConnectX-7 QSFP112 adapters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003e800G OSFP SR8 (MMA4Z00-NS)\u003c\/a\u003e — the switch-side module, two cables per unit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mpo-12-apc-os2-single-mode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-dr-class-single-mode-optics\"\u003eMPO-12\/APC OS2 single-mode trunk cable\u003c\/a\u003e — for DR-class single-mode modules\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/mpo-12-apc-1-2-splitter-cable-custom-build\"\u003eMPO-12\/APC 1:2 splitter cables\u003c\/a\u003e — built to order, for NDR200 fan-out from a twin-port switch port\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/blogs\/news\/mpo-12-apc-vs-upc-ndr-fiber-guide\"\u003eMPO-12\/APC vs UPC: why your existing fiber won't work with NDR optics\u003c\/a\u003e — endface, pinning, polarity and key orientation in full\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/nvidia-osfp-transceiver-part-number-crosswalk\"\u003eNVIDIA OSFP part-number crosswalk\u003c\/a\u003e — pin down the exact optic behind a part number before you order fiber for it\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/dac-cables\"\u003eOSFP DAC cables\u003c\/a\u003e — for in-rack runs where copper is the better answer than fiber\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/transceivers\"\u003eTransceivers\u003c\/a\u003e — the rest of the optics catalog\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resilient Tec","offers":[{"title":"1 m","offer_id":49231053848676,"sku":"RT-MPOAPC-OM4-01M","price":59.0,"currency_code":"USD","in_stock":true},{"title":"3 m","offer_id":49231053881444,"sku":"RT-MPOAPC-OM4-03M","price":69.0,"currency_code":"USD","in_stock":true},{"title":"5 m","offer_id":49231053914212,"sku":"RT-MPOAPC-OM4-05M","price":79.0,"currency_code":"USD","in_stock":true},{"title":"10 m","offer_id":49231053946980,"sku":"RT-MPOAPC-OM4-10M","price":99.0,"currency_code":"USD","in_stock":true},{"title":"15 m","offer_id":49231053979748,"sku":"RT-MPOAPC-OM4-15M","price":119.0,"currency_code":"USD","in_stock":true},{"title":"20 m","offer_id":49231054012516,"sku":"RT-MPOAPC-OM4-20M","price":139.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/Screenshot2026-09-17170800.png?v=1789679479"},{"product_id":"mpo-12-apc-os2-single-mode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-dr-class-single-mode-optics","title":"MPO-12\/APC OS2 Single-Mode Trunk Cable, Type B, Female-to-Female — for NVIDIA DR-Class Optics","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e This is an MPO-12\/APC OS2 single-mode trunk cable, Type B crossover, female\/unpinned on both ends, with all 12 fibers terminated and keyed up to down for APC. It is built for NVIDIA DR-class single-mode optics such as the 400G DR4 (MMS4X00-NS400) and 800G 2×DR4 (MMS4X00-NM). Available in 1, 3, 5, 10, 15 and 20 m. Resilient Tec sells it new, with a lifetime warranty and free US shipping from Knoxville, TN.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDR-class single-mode optics require APC. The UPC cords from your 100G or 200G fabric will not mate with them.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an MPO-12 trunk cable with \u003cstrong\u003eangle-polished (APC) endfaces\u003c\/strong\u003e on OS2 9\/125 single-mode fiber, built to the polarity and gender NVIDIA DR-class optics actually need: \u003cstrong\u003eType B crossover, female\/unpinned on both ends, all 12 fibers terminated.\u003c\/strong\u003e Yellow jacket, green connector housings, OFNP plenum rated.\u003c\/p\u003e\n\u003cp\u003eIf your modules are single-mode DR-class — not the multimode SR4\/SR8 parts — this is the cable.\u003c\/p\u003e\n\n\u003ch2\u003eAPC vs UPC — read this before you order\u003c\/h2\u003e\n\u003cp\u003eAn APC connector has an \u003cstrong\u003e8° angled endface\u003c\/strong\u003e. A UPC connector is flat. They cannot mate. Put them together and you get an air gap, an unusable return loss figure, and a link that either never comes up or comes up and drifts.\u003c\/p\u003e\n\u003cp\u003eThe 100G (4×25G NRZ) and 200G (4×50G PAM4) generations were overwhelmingly \u003cstrong\u003eUPC\u003c\/strong\u003e. The NDR and XDR generations moved to \u003cstrong\u003eAPC\u003c\/strong\u003e. A customer upgrading an existing fabric does not carry their patch cords forward. This is the most common ordering mistake in an upgrade, and most supplier pages never mention it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to tell at a glance:\u003c\/strong\u003e a green connector housing means APC — NVIDIA's own module documentation describes the MPO-12\/APC interface as having a green plastic shell. The \u003cem\u003ejacket\u003c\/em\u003e color tells you the fiber type — yellow is single-mode — not the endface. Two different things, and easy to conflate. Jacket colors also vary between manufacturers; the connector housing is the reliable answer.\u003c\/p\u003e\n\n\u003ch2\u003eKey orientation: key-up to key-down\u003c\/h2\u003e\n\u003cp\u003eThe industry shorthand \"Type B means key-up to key-up\" is a \u003cstrong\u003eUPC\u003c\/strong\u003e rule, and it does not transfer to APC. Two 8° angled endfaces have to be complementary to seat, so an APC Type B assembly mates \u003cstrong\u003ekey-up to key-down\u003c\/strong\u003e — Modified Method B, a Type B cable through Type A (key-up\/key-down) adapters.\u003c\/p\u003e\n\u003cp\u003eThis cable is built key-up to key-down, confirmed in writing by the manufacturer. It is worth checking whatever else you are buying: it is not unusual to find a part listed as APC and \"female key-up to female key-up\" on the same page, which cannot physically mate.\u003c\/p\u003e\n\n\u003ch2\u003eFully terminated 12-fiber — and why that is a feature\u003c\/h2\u003e\n\u003cp\u003eAll twelve positions are terminated in a Type B crossover: position 1 lands on position 12, 2 on 11, and so on across the connector.\u003c\/p\u003e\n\u003cp\u003eA DR4 module uses four lanes in each direction. NVIDIA's own MFP7E30 single-mode cable is built with \u003cstrong\u003eeight\u003c\/strong\u003e fibers populated — positions 1–4 and 9–12, with 5–8 left unconnected — because that is all a DR4 link needs. Ours terminates all twelve. In a DR4 link the two are interchangeable: the module's four transmit positions land on the far end's four receive positions either way, and the extra pairs simply carry no traffic.\u003c\/p\u003e\n\u003cp\u003eThe difference shows up later. A fully terminated assembly can be re-tested end to end, can carry a different lane map if you repurpose it, and does not leave you guessing which positions were populated when a link goes marginal two years from now.\u003c\/p\u003e\n\n\u003ch2\u003eSingle-mode is not a speed bump\u003c\/h2\u003e\n\u003cp\u003eThe DR-class generation moved from SR\/multimode to DR\/single-mode. That is a change to your fiber plant, not just a faster module. \u003cstrong\u003eA multimode cable will not substitute for this one regardless of endface\u003c\/strong\u003e, and an OM4 cable in a DR4 port fails differently from an APC\/UPC mismatch — it will look like a loss problem rather than a mating problem, and you will spend an afternoon on it.\u003c\/p\u003e\n\n\u003ch2\u003eWhich one do I need?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModule\u003c\/th\u003e\n\u003cth\u003ePorts\u003c\/th\u003e\n\u003cth\u003eCable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mms4x00-ns400-compatible-400g-osfp-dr4-flat-top-rhs-transceiver-connectx-7\"\u003eMMS4X00-NS400\u003c\/a\u003e — 400G OSFP DR4, flat-top (NIC side)\u003c\/td\u003e\n\u003ctd\u003e1× MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eThis cable\u003c\/strong\u003e — one per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"\/products\/mms4x00-nm-compatible-800g-osfp-2xdr4-twin-port-transceiver-quantum-2\"\u003eMMS4X00-NM\u003c\/a\u003e — 800G OSFP 2×DR4, twin-port (switch side)\u003c\/td\u003e\n\u003ctd\u003e2× MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eThis cable\u003c\/strong\u003e — two per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultimode SR4 \/ SR8 modules\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003eUse the \u003ca href=\"\/products\/mpo-12-apc-om4-multimode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-ndr-400g-800g-optics\"\u003eOM4 multimode\u003c\/a\u003e version instead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTwin-port rule:\u003c\/strong\u003e both ports on a twin-port module must run the same fiber type. Do not mix.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMPO-12 \/ APC, 8° angled endface, green housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGender\u003c\/td\u003e\n\u003ctd\u003eFemale \/ unpinned, both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber count\u003c\/td\u003e\n\u003ctd\u003e12 positions, all 12 terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eType B crossover (position 1 to position 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey orientation\u003c\/td\u003e\n\u003ctd\u003eKey-up to key-down (Modified Method B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber\u003c\/td\u003e\n\u003ctd\u003eOS2 9\/125 single-mode, yellow jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsertion loss\u003c\/td\u003e\n\u003ctd\u003e≤0.35 dB per connector, low-loss grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket rating\u003c\/td\u003e\n\u003ctd\u003eOFNP (plenum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLengths\u003c\/td\u003e\n\u003ctd\u003e1, 3, 5, 10, 15, 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003ePricing by length\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-01M\u003c\/td\u003e\n\u003ctd\u003e$55.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-03M\u003c\/td\u003e\n\u003ctd\u003e$59.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-05M\u003c\/td\u003e\n\u003ctd\u003e$65.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-10M\u003c\/td\u003e\n\u003ctd\u003e$85.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-15M\u003c\/td\u003e\n\u003ctd\u003e$103.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 m\u003c\/td\u003e\n\u003ctd\u003eRT-MPOAPC-OS2-20M\u003c\/td\u003e\n\u003ctd\u003e$121.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eVolume:\u003c\/strong\u003e 10 or more of any one length, 10% off. 25 or more, 18% off. Quoted at checkout or on a pod quote.\u003c\/p\u003e\n\n\u003ch2\u003eGood to know\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFemale\/unpinned is correct.\u003c\/strong\u003e NVIDIA's single-mode DR-class modules carry the alignment pins; the fiber connector carries the matching holes. Pinned MPO connectors belong on permanent-link backbone cabling that lands in a patch panel, not on the cable that plugs into an optic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFNP, not riser.\u003c\/strong\u003e This cable is plenum-rated. NVIDIA's own MFP7E30 single-mode assemblies are specified LSZH-OFNR — riser. If your run crosses a plenum air-handling space, OFNR is not code-compliant and OFNP is.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe connectors are the loss budget.\u003c\/strong\u003e At data-center distances single-mode fiber contributes almost nothing to attenuation. Nearly all of your loss is in the mated pairs, which is why low-loss grade matters far more here than length does.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReach is generous; junctions are not.\u003c\/strong\u003e DR-class single-mode modules are rated to 500 m, so at patch-cable lengths distance is not your constraint. Every additional MPO mating in the path is, and a link with several patch-panel hops eats budget quickly. Count junctions, not meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eQuick checklist — is this the right cable?\u003c\/h2\u003e\n\u003cp\u003eYour optics are DR-class and take MPO-12\/\u003cstrong\u003eAPC\u003c\/strong\u003e. Your fiber plant is \u003cstrong\u003esingle-mode\u003c\/strong\u003e (OS2). You need a \u003cstrong\u003estraight\u003c\/strong\u003e cable, not a 1:2 splitter. Your run still fits its loss budget with the connector junctions in the path.\u003c\/p\u003e\n\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIn stock at Resilient Tec in all six lengths.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShipped from Knoxville, Tennessee. Free standard shipping on all US orders, no minimum. Populating a pod? Tell us your node count and module part numbers and we will quote the cables and the optics together. \u003ca href=\"\/pages\/request-a-quote\"\u003eRequest a quote →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e lifetime, \u003ca href=\"\/pages\/lifetime-warranty\"\u003ebacked by Resilient Tec\u003c\/a\u003e — not a manufacturer term. When something fails you reach a named seller in Knoxville, not a ticket queue.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with multimode SR4\/SR8 optics?\u003c\/strong\u003e\u003cbr\u003eNo. SR4 and SR8 optics are multimode and need OM4 fiber. Use the OM4 MPO-12\/APC trunk for those.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I reuse my 100G\/200G MPO cords with DR-class optics?\u003c\/strong\u003e\u003cbr\u003eNo. Earlier generations were mostly MPO UPC; DR-class NDR optics use MPO APC. The endfaces cannot mate, so upgrades need new APC cords.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat warranty and shipping come with it?\u003c\/strong\u003e\u003cbr\u003eResilient Tec's lifetime warranty. US standard shipping is free with no minimum, and orders typically arrive in 3 to 5 days.\u003c\/p\u003e\n\u003ch2\u003eYou might also need\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mms4x00-ns400-compatible-400g-osfp-dr4-flat-top-rhs-transceiver-connectx-7\"\u003e400G OSFP DR4 (MMS4X00-NS400)\u003c\/a\u003e — the NIC-side module this cable plugs into, one cable per module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mms4x00-nm-compatible-800g-osfp-2xdr4-twin-port-transceiver-quantum-2\"\u003e800G OSFP 2×DR4 twin-port (MMS4X00-NM)\u003c\/a\u003e — the switch-side module, two cables per module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mpo-12-apc-om4-multimode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-ndr-400g-800g-optics\"\u003eMPO-12\/APC OM4 multimode trunk cable\u003c\/a\u003e — the multimode equivalent, for SR4\/SR8 modules\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/pages\/nvidia-osfp-transceiver-part-number-crosswalk\"\u003eNVIDIA OSFP part-number crosswalk\u003c\/a\u003e — confirm whether your module is single-mode DR or multimode SR before you order fiber for it\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/transceivers\"\u003eTransceivers\u003c\/a\u003e — the rest of the optics catalog\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/dac-cables\"\u003eOSFP DAC cables\u003c\/a\u003e — for in-rack runs where copper is the better answer than fiber\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resilient Tec","offers":[{"title":"1 m","offer_id":49231056470116,"sku":"RT-MPOAPC-OS2-01M","price":55.0,"currency_code":"USD","in_stock":true},{"title":"3 m","offer_id":49231056502884,"sku":"RT-MPOAPC-OS2-03M","price":59.0,"currency_code":"USD","in_stock":true},{"title":"5 m","offer_id":49231056535652,"sku":"RT-MPOAPC-OS2-05M","price":65.0,"currency_code":"USD","in_stock":true},{"title":"10 m","offer_id":49231056568420,"sku":"RT-MPOAPC-OS2-10M","price":85.0,"currency_code":"USD","in_stock":true},{"title":"15 m","offer_id":49231056601188,"sku":"RT-MPOAPC-OS2-15M","price":103.0,"currency_code":"USD","in_stock":true},{"title":"20 m","offer_id":49231056633956,"sku":"RT-MPOAPC-OS2-20M","price":121.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/mpo-12-apc-os2-single-mode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-dr-class-single-mode-optics_1.jpg?v=1793196552"},{"product_id":"mms4x00-nm-compatible-800g-osfp-2xdr4-twin-port-transceiver-quantum-2","title":"NVIDIA MMS4X00-NM Compatible 800G OSFP 2×DR4 Twin-Port Transceiver — Dual MPO-12\/APC SMF, 1310nm, 500m — Finned-Top or Flat-Top","description":"\u003cp\u003e\u003cstrong\u003eTwin-port 800G, single-mode. Two ports means two cables.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNVIDIA MMS4X00-NM compatible — 800 Gb\/s twin-port OSFP, \u003cstrong\u003etwo independent 400G DR4 ports\u003c\/strong\u003e, 1310 nm single-mode, dual MPO-12\/APC interfaces, rated to 500 m. Coded for NVIDIA. For Quantum-2 QM9700 and QM9790 switches and DGX-class links.\u003c\/p\u003e\n\n\u003ch2\u003eWhich one do I have?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eYour hardware\u003c\/th\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003cth\u003eChoose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantum-2 QM9700 \/ QM9790, air-cooled switch chassis\u003c\/td\u003e\n\u003ctd\u003eChassis airflow over an integrated heat sink\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFinned-Top (IHS)\u003c\/strong\u003e — MMS4X00-NM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid-cooled systems, DGX-class links\u003c\/td\u003e\n\u003ctd\u003eCold plate or system-level cooling, flat module top\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFlat-Top (RHS)\u003c\/strong\u003e — MMS4X00-NM-FLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese are two different NVIDIA part numbers, not two finishes. The optics are identical; the thermal design is not, and the wrong one will not cool correctly in your chassis. If you are unsure, the part number printed on the module you are replacing is the answer — or send us a photo and we will tell you.\u003c\/p\u003e\n\n\u003ch2\u003eTwo ports, two cables, one fiber type\u003c\/h2\u003e\n\u003cp\u003eEach port is an independent 400G DR4 link with its own MPO-12\/APC interface. A fully populated module needs \u003cstrong\u003etwo\u003c\/strong\u003e MPO-12\/APC OS2 single-mode cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwin-port rule:\u003c\/strong\u003e both ports must run the same fiber type. Do not mix a single-mode cable in one port and something else in the other.\u003c\/p\u003e\n\n\u003ch2\u003eSingle-mode DR, not multimode SR\u003c\/h2\u003e\n\u003cp\u003eDR-class is \u003cstrong\u003esingle-mode\u003c\/strong\u003e — OS2 9\/125, 1310 nm, 500 m. The SR-class modules of the same generation are multimode at 850 nm and 50 m. Same OSFP cage, same MPO-12\/APC connector, completely different fiber plant. Confirm which class your fabric is built on before ordering either the modules or the cable.\u003c\/p\u003e\n\u003cp\u003eAnd as with everything in this generation: the interface is \u003cstrong\u003eAPC\u003c\/strong\u003e. UPC cords from a 100G or 200G fabric will not mate.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eOSFP twin-port — finned-top (IHS) or flat-top (RHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e2 × MPO-12\/APC, independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData rate\u003c\/td\u003e\n\u003ctd\u003e400 Gb\/s per port · 800 Gb\/s total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSingle-mode fiber (OS2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1304.5–1317.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReach\u003c\/td\u003e\n\u003ctd\u003eup to 500 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC, pinned, green housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax power\u003c\/td\u003e\n\u003ctd\u003e16 W · 1.5 W low-power mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDOM\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoding\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLifetime, backed by Resilient Tec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBoth versions in stock at Resilient Tec:\u003c\/strong\u003e finned-top (IHS) for air-cooled Quantum-2 switches and flat-top (RHS) for DGX-class and liquid-cooled systems. Quantities are limited. For a larger order, tell us your quantity and we will quote it. \u003ca href=\"\/pages\/request-a-quote\"\u003eRequest a quote →\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eShipped from Knoxville, Tennessee. Free standard shipping on all US orders, no minimum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e lifetime, \u003ca href=\"\/pages\/lifetime-warranty\"\u003ebacked by Resilient Tec\u003c\/a\u003e — not a manufacturer term.\u003c\/p\u003e\n\n\u003ch2\u003eYou might also need\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mpo-12-apc-os2-single-mode-fiber-patch-cord-type-b-female-unpinned-low-loss-for-nvidia-dr-class-single-mode-optics\"\u003eMPO-12\/APC OS2 single-mode trunk cable\u003c\/a\u003e — \u003cstrong\u003etwo per module\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/nvidia-osfp-transceiver-part-number-crosswalk\"\u003eNVIDIA OSFP part-number crosswalk\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/mma4z00-ns-compatible-800g-osfp-sr8-finned-top-ihs-transceiver-quantum-2\"\u003e800G OSFP SR8 (MMA4Z00-NS)\u003c\/a\u003e — the multimode equivalent, if your plant is OM3\/OM4\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/transceivers\"\u003eTransceivers\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Resilient Tec","offers":[{"title":"Finned-Top (IHS) — air-cooled switches, Quantum-2 QM9700 \/ QM9790","offer_id":49280963280996,"sku":"MMS4X00-NM","price":999.0,"currency_code":"USD","in_stock":true},{"title":"Flat-Top (RHS) — liquid-cooled systems and DGX-class links","offer_id":49280963313764,"sku":"MMS4X00-NM-FLT","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/3482\/4548\/files\/IMG_5120.jpg?v=1788898588"}],"url":"https:\/\/resilient-tec.com\/collections\/quantum-2-qm9700-cables-optics.oembed","provider":"Resilient Tec","version":"1.0","type":"link"}